Advanced Chemical Sensors, Inc.
Technical Information Sheet
BTEX + Saturated Hydrocarbons Vapor Monitor
Catalog No. OV-095
The Monitor will measure the actual concentrations of petroleum-based solvents such as benzene, toluene, ethyl benzene, xylene, and saturated hydrocarbons in the series from pentane to dodecane.
Minimum Levels of Detection (Based on an 8 hour Exposure Time)
| |
ppm |
micrograms/cubic meter |
| Benzene |
0.02 |
50 |
| Toluene |
0.03 |
110 |
| Ethyl Benzene |
0.03 |
130 |
| Xylene |
0.03 |
130 |
| Total Saturated Hydrocarbons |
0.1 |
375 |
(Total saturated hydrocarbons are usually reported as Hexane equivalent. Individual chemicals such as pentane, hexane, heptane, octane, etc can be reported.)
Minimum Levels of Detection (Based on an 24 hour Exposure Time)
| |
ppm |
micrograms/cubic meter |
| Benzene |
0.007 |
17 |
| Toluene |
0.01 |
37 |
| Ethyl Benzene |
0.01 |
43 |
| Xylene |
0.01 |
43 |
| Total Saturated Hydrocarbons |
0.03/td>
| 125 |
(Total saturated hydrocarbons are usually reported as Hexane equivalent. Individual chemicals such as pentane, hexane, heptane, octane, etc can be reported.)
For an exposure time of 48 hours the minimum levels of detection are 1/2 of the values reported for a 24 hour exposure.
| Exposure Limits: |
OSHA-TWA (ppm) |
OSHA-STEL (ppm) |
| Benzene |
1 |
5 |
| Toluene |
200 |
C 300 |
| Ethyl Benzene |
100 |
None |
| Xylene |
100 |
None |
| Total Saturated Hydrocarbons |
500 |
None |
C: Ceiling Limit
| Sampling Medium: |
Activated High-Purity Carbon Molecular Sieve |
| Method of Analysis: |
Gas Chromatogratphy |
| Recommended Sampling Time: |
15 minutes to 48 hours |
| Interferences: |
No interferences are known. |
| Effect of Temperature: |
Less than 10% for each 10 °C variation from 24 °C |
| Effect of Humidity: |
No effects detected at 30% RH to 92% RH. |
| Storage Conditions: |
Maximum shelf life one year. |
| Recommended Holding Time: |
Two weeks prior to analysis. |
|