Advanced Chemical Sensors, Inc.
Technical Information Sheet
Nitrous Oxide Vapor Monitor
Catalog No. N-10
ACS Vapor Monitor can be worn as a badge near the breathing zone
to measure personal exposure, or placed in a room to measure area
concentration.
Occupational safety standards are based on personal exposure
monitoring of each employee who may be exposed to the vapor as a
regular part of their job. Periodic monitoring of personnel and room
concentrations is recommended
| Exposure Limits: |
ACGIH |
OSHA |
NIOSH |
| TWA (ppm) |
50 |
N/A |
25 |
| STEL/CEIL (ppm) |
N/A |
N/A |
N/A |
| Sampling Medium: |
Activated Sodium Alumino Silicate Molecular Sieve Adsorbent |
| Reference Method: |
NIOSH Method 6600 |
| Recommended Sampling Time: |
30 minutes to 8 hours |
| Minimum Level of Quantitation: |
1 ppm for 1 hour |
| Interferences: |
No interferences are known.
|
| Effect of Temperature: |
Less than 15% between 56 °F and 111 °F |
| Effect of Humidity: |
No effects detected at 30% RH to 92% RH. |
| Overall System Accuracy: |
Better than +/-16% at 25 ppm for 8 hours
Coefficient of Variation = 0.039
Found to be the only accurate monitoring badge by
the American Dental Association.
|
| Storage Conditions: |
Maximum shelf life one year. |
| Recommended Holding Time: |
Two weeks prior to analysis. |
|