Technical Information Sheet

Phenol Vapor Monitor
Catalog No. OV-85

ACS Vapor Monitor can be worn as a badge near the breathing zone to measure personal exposure, or placed in a room to measure area concentration.

Occupational safety standards are based on personal exposure monitoring of each employee who may be exposed to the vapor as a regular part of their job. Periodic monitoring of personnel and room concentrations is recommended


Exposure Limits: ACGIH OSHA NIOSH
TWA (ppm) 5 5 5
STEL/CEIL (ppm) N/A N/A 15.6

Sampling Medium: Activated High Porosity Polymer Adsorbent
Method of Analysis: Gas Chromatography
Reference Method: US NIOSH Method 3502
Recommended Sampling Time: 1 hour to 8 hours
Minimum Level of Quantitation: 3 micrograms per sample:
0.1 ppm for 8 hour period
Interferences: No interferences are known.
Effect of Temperature: Less than 10% for each 10 °C variation from 24 °C
Effect of Humidity: No effects detected at 30% RH to 92% RH.
Overall System Accuracy: 12.2% at 5.0 ppm for 8 hours
Storage Conditions: Maximum shelf life one year.
Recommended Holding Time: Two weeks prior to analysis.