Accurate, Cost-Effective Chemical Analysis and Monitoring

Advanced Chemical Sensors, Inc.
Technical Information Sheet

Acrolein Vapor Monitor
Catalog No. OV-055

ACS Vapor Monitor can be worn as a badge near the breathing zone to measure personal exposure, or placed in a room to measure area concentration.

Occupational safety standards are based on personal exposure monitoring of each employee who may be exposed to the vapor as a regular part of their job. Periodic monitoring of personnel and room concentrations is recommended


Exposure Limits: ACGIH OSHA NIOSH
TWA (ppm) N/A 0.1 0.1
STEL/CEIL (ppm) 0.1 N/A 0.3

Sampling Medium: Chemically Activated Silica Gel
Method of Analysis: High Performance Liquid Chromatography (HPLC)
Recommended Sampling Time: 15 minutes to 8 hours
Minimum Level of Quantitation: 0.01 ppm for 8 hours
0.3 ppm for 15 minutes; 0.1 ppm with field blank
Interferences: No interferences are known.
Effect of Temperature: Less than 10% for each 10 °C variation from 24 °C
Effect of Humidity: No effects detected at 30% RH to 92% RH.
Overall System Accuracy: 18% at 0.1 ppm for 8 hours
Storage Conditions: Maximum shelf life 6 months.
Recommended Holding Time: One week prior to analysis.